Venue Technical Information

SYSTEM: ACTIVE

EVENTFINDA STADIUM // TECHNICAL CAPACITY INDEX

REF: PRO-GUIDE_2026_V3

Auckland's premier international-level indoor arena infrastructure profile. Three decades of architectural flexibility, engineered to eliminate delivery constraints and maximize production footprint scaling.

[01] REGIONAL CATCHMENT & LOGISTICS MATRIX

POPULATION REACH
388,071
North Shore / Rodney
AVG HOUSEHOLD INC
$163,417
Catchment Territory
TICKETING DATABASE
450,000
Global Profiles
LOCALIZED CRM
62,000
Active Contacts

LOADING BAY & FREIGHT LOGISTICS

LOGISTICS PARAMETERDATA TRACK / CAPACITY SPECIFICATION
LOADING BAY ACCESSDirect entry into the venue via the Southwestern Carpark footprint
EXTERNAL DOOR CLEARANCE2800mm Width x 2900mm Height
GROUND LOAD PASSSolid concrete pad extending directly out to the edge of Court 4
LOGISTICS NOTE: Located 9km from Auckland CBD. Dual vehicular access gates via Argus Pl / Silverfield Pl. Close proximity to Northern Busway & twin motorway interchanges. Charter event bus loops support a 10-minute turnaround window. Full disability integration engineered throughout.

[02] MAIN HALL & STRUCTURAL SURFACE PARAMETERS

SURFACE FOOTPRINT: 2,400 m² FIBA T1 Certified Sprung Wooden Junckers Unobat 50 Sports Floor (34.8m x 75.0m clear span).
SURFACE PROTECTION: Modular in-house carpet-tile barrier layout available to blanket full ground floor footprint.

ENGINEERING FIELD FLOOR-LOADING CONSTRAINTS

VEHICLE / CONDITION CLASSMAXIMUM WEIGHTMANDATORY PROTECTION & COMPLIANCE PARAMS
MAXIMUM OVERALL LOAD1,000 kg / m²Absolute threshold ceiling across any single square meter of floor surface.
LIGHT VEHICLES (Cars, Vans, Small Trucks)Up to 2,500 kgMust run on minimum of 4 pneumatic rubber tires (no hard wheels). Velocity locked at 5km/hr. Surface must be protected by protective carpet layering.
HEAVY OPERATIONAL VEHICLESUp to 4,000 kgPermitted explicitly depending on precise wheel geometry configuration. Floor surface must be completely sheeted with a minimum of 20mm structural plywood overlays.
VEHICULAR ACCESS SIGN-OFFALL VEHICLESPrior formal authentication from the Operations Manager is strictly required before any vehicle crosses the threshold.

SEATING SECTOR BREAKDOWN (MAX CAPACITY: 5,200 PAX)

SECTOR LOCATIONDESIGNATION BLOCKSTHRESHOLD CAPACITY
LOWER TIER BACK / SIDESSections 201 - 2071,171 PAX
LOWER TIER FRONT / RISERSSections 209 - 211527 PAX
MEZZANINE BOX CONFIGURATIONSSections 301 - 304236 PAX
GROUND FLOOR GRIDGeneral Admission (GA) Floor3,266 PAX
COMBINED TOTAL VENUE CAPACITYALL AVAILABLE ARCHITECTURE5,200 PAX

[03] STAGE INFRASTRUCTURE, POWER LOGIC & NETWORK PORTALS

STAGE MECHANICS SPECIFICATIONS

INFRASTRUCTURE COMPONENTENGINEERING SPECIFICATION / CONFIGURATION
STAGE SYSTEMShowquip modular touring stage system (Spark Arena compliant dimensions)
DECK DIMENSIONS40ft x 40ft structural footprint
HEIGHT SELECTIONSLocking pins engineered for vertical heights at: 1200mm, 1500mm, and 1800mm
ACCESS ACCESSORIES1x Integrated equipment loading ramp // 2x Heavy-duty staff stair assemblies

POWER SUPPLY MATRIX (VENUE POWER & HEAVY RACKS)

TRANSFORMER SPECIFICATION: The venue is supplied directly by a dedicated on-site 300 Kva three-phase 415V master transformer (completely replaced in 2023). Internally, primary production stage power is supplied by high-safety industrial Power Safe line source connectors (Power locks).
CORE POWER PROFILESQTYCONNECTION TERMINATION SPECIFICATION
STAGE PRODUCTION LINKS160A 3-Phase Ceeform terminal (Located Upstage Ground Level)
232A 3-Phase Ceeform connections (Located Upstage Ground Level)
MAIN PRODUCTION HOUSING RUNS332A 3-Phase Ceeform connectors configured upstage left
AUXILIARY SITE DISTRIBUTION632A 3-Phase PDL outlets positioned throughout the venue footprint
SYSTEM DISTRIBUTION RUNS263A 3-Phase Ceeform ports (Split South Service corridor & Main Storeroom nodes)
HIGH CAPACITY FEEDER LINK1100A 3-Phase Ceeform connection terminal (Terminated Upstage Left)

NETWORK PIPELINES & HIGH-SPEED BACKBONE

DATA CONNECTION TYPEBANDWIDTH PROFILENETWORK ACCESS & ROUTING CORE HARDWARE
PRIMARY SYSTEM FIBER1,000 / 1,000 MBDedicated UFB Vodafone Fibre roadside connection entry point
SECONDARY SECURE PIPELINE200 / 200 MBDedicated Kordia Fibre routing infrastructure network path
IN-VENUE WIRELESS NETWORKSWiFi 5 & 6+ FormatsComprehensive coverage distributed via Ubiquiti UniFi UAP-AC-PRO Dual-band AC1750 array throughout the venue floors. Managed via Ubiquiti UniFi Cloud Controller and localized Security Gateways. Load balancing is entirely hardware-based.

STRUCTURAL CEILING RIGGING & SUPPORT SPACE QUANTITIES

CRITICAL CEILING RIGGING CONSTRAINTS: Overhead roof architecture features a maximum 1000kg safe working load limit. High catwalk system access equipped with structural safety lines is available in the internal roof space exclusively to approved contractors. All structural Rigging Plans must be officially signed off by a designated Eventfinda Stadium engineer (associated processing costs are the responsibility of the hiring client).
INFRASTRUCTURE HUBALLOTMENT QUANTITYCORE CAPABILITIES & INCLUDED HARDWARE
OVERHEAD RIGGING GRID1 Truss Box10m x 10m ceiling configuration running on 4x IT CM Loadmaster automated motors
ARTIST DRESSING ROOMS2 RoomsPremium backstage allocations with independent climate control and en-suite toilet/shower
STANDARD CHANGING FACILITIES4 RoomsMulti-stall layouts with full toilet/shower blocks (convertible to production operations)
PROMOTERS OFFICE1 HubPrivate, secure executive space adjacent to Main Entry, Ticket Box, and arena floor
FIRST AID EMERGENCY SUITE1 SuiteMedical-compliant configuration featuring dedicated independent toilet and shower stalls
VIP HOSPITALITY LOUNGE1 LoungeReception space directly flanking the venue bar area and commercial kitchen portals

[04] PRODUCTION HARDWARE, HOUSE AV & ENVIRONMENTAL ACOUSTICS

VENUE LED VIDEO DISPLAY SCREENS

HARDWARE TERMINATION LOCATIONQTYPHYSICAL DIMENSIONSRESOLUTION & HARDWARE DATA CONSTRAINTS
MAIN ARENA STADIUM CORE2 Units3m x 4m Display Block3.9mm SMD LED Screen natively scaling to 1920 x 1080. Fed directly from the venue videopro scoreboard score system framework via independent HDMI or SDI master inputs. Automated hardware scale profile locks to a 16:10 aspect ratio. Screens are bound under the Venue Hire Agreement (VHA); a dedicated operator is not supplied.
MAIN RECEPTION FOYER HUB1 Unit3m x 4m Display BlockPremium 4mm SMD LED Screen displaying at 1920 x 1080 high-contrast resolution.

ENVIRONMENTAL ACOUSTIC MATRIX & NOISE COERCION LIMITS

ENVIRONMENTAL MONITORING MANDATE: The venue noise level from any on-site production activity, calculated at the boundary perimeter of adjacent residential properties, must not exceed the statutory limits outlined below. Verified under NZS 6801:2008 and NZS 6802:2008. No single 5-minute tracking sample can exceed these parameters.
OPERATIONAL TIME SEGMENT CALIBRATIONMAXIMUM PERMISSIBLE AUDIBLE LIMIT ($A_{eq}$ 5-Min)
MONDAY TO SATURDAY // 0700 HR – 2200 HR55 dBA
SUNDAYS & PUBLIC HOLIDAYS // 0900 HR – 1800 HR55 dBA
ALL OTHER TIME SLOTS / REVENUE PERIMETERS45 dBA
NIGHT COERCION LOCK // 2200 HR – 0700 HR ARRIVAL75 dBA Lmax

BROADCAST STREAMING & DRY HIRE HARDWARE

BROADCAST STREAMING CAPABILITIES: Professional video streaming infrastructure is provided directly through Kordia network links. Eventfinda Stadium explicitly prohibits live broadcast streaming over public or in-venue Wi-Fi networks. Coordinated through your Event Coordinator.

IN-HOUSE AV DRY HIRE COLLECTION: On-site inventory includes a multi-channel production Vision Mixer console, mobile data projectors, and peripheral PA speakers. The core building PA system uses a central speaker cluster suspended above the main floor, supplemented by 1x integrated system wireless microphone link.

PREFERRED CONCERT GEAR OVERVIEW: Live front-of-house reinforcement, automated lighting arrays, and media servers run natively through venue partner College Hill Productions. Hardware allocations are indexed below.

COLLEGE HILL PRODUCTION GEAR ALLOCATIONS

HARDWARE CATEGORYQTYHARDWARE MODEL / DESCRIPTION
LIVE AUDIO FOH / PA16L'Acoustics V-DOSC Line Array Elements (Split Left/Right, 8 per side)
6L'Acoustics dV-DOSC Line Array Elements (Used as array underhangs, 3 per side)
12L'Acoustics SB218 Dual 18" High-Power Subwoofers
8L'Acoustics ARCS 2-Way Constant Curvature Enclosures
-Crown Macro-Tech Amplification systems to suit complete array integration
AUDIO MIXING & SYSTEM DRIVE1Allen & Heath dLive S5000 Dual-Screen Control Surface
1Allen & Heath dLive CDM64 Digital Stage Box Engine
280m CAT6 Ethercon Heavy Digital Snake Cable Reels
1Dolby Lake Drive Rack 02 (Analogue Main Signal Control Router)
3Dolby LP4D12 Lake Processors + 1x BSS FCS960 Dual Graphic EQ Stack
STAGE MONITORING & MICROPHONES10L'Acoustics 115FM 2-Way Coaxial Floor Monitors (Providing 8 discrete sends)
2QSC 4-Send Bi-Amplified Monitor Drive Tour Racks
6Countryman Type 85 Active Direct Injection (DI) Boxes
2BSS AR133 Active Direct Injection (DI) Boxes // 1x Whirlwind ISO2 Unit
6Shure Beta 58A Premium Vocal Dynamic Microphones
6Shure SM57 Cardioid Dynamic Instrument Microphones
16Tall Boom Microphone Stands (Black) // 16x Short Boom Stands
-Dynamic capture lineup: Shure Beta (91A/52A/56A), SM81, KSM137, AKG C214, Sennheiser e904/MD421
AUTOMATED PERFORMANCE LIGHTING8Martin MAC Viper Profile Moving Head Luminaires (Flown on Front Truss)
16MegaPointe CMY Moving Head Profile Clones (Split evenly: 8x Mid, 8x Back Truss)
16B-Eye K10 Moving Head Wash Clones (Split evenly: 8x Mid, 8x Back Truss)
84-Way Audience Blinders (Flown across Mid and Back Truss sections)
1High End Systems Hog Full Boar 4 Professional Lighting Console
-System Distribution: 1x 63A Power Distro Rack, 2x 8-way ArtNet DMX Nodes, 24-way Dimmer Rack
ATMOSPHERE & DISPLAY MEDIA2Digital Oil Hazers // 2x Black Variable Industrial Atmosphere Extraction Fans
80MS P3.91 Modular LED Display Panels (Individual dimensions: 500mm x 1000mm)
18m x 5m Upstage LED Video Wall Configuration (Total Array)
1Novastar K16 High-Capacity LED Video Processor Engine
1Lenovo Legion High-Spec Media Laptop running licensed Resolume Server Software

[05] SPECIALIZED PERFORMANCE PACKAGES (LUX PRODUCTIONS OPTIMIZATION)

Alternative tournament and high-output stadium music performance presets are deployed directly through specialized hardware lines from Lux Productions.

A. COMPACT COMBAT SPORTS / BOXING LIGHTING PRESET [QUANTITY LOG]

HARDWARE SEGMENTQTYHARDWARE MODEL / CAPABILITY DESIGNATION
GRID LIGHTING FIXTURES4Chauvet Maverick Mk2 Moving Head Wash
8Chauvet Maverick Mk3 Moving Head Wash
12Ayrton Eurus Moving Head Profile
8Fusion Hex Par IP Apron / Ring Fill Fixtures
CONTROL & NETWORKING1Onyx NX2 Lighting Console
1Onyx EN12 Advanced Routing Node
1Onyx EN4 Distribution Node
1Onyx NS8 Network Data Switch
POWER & LOOM RUNS163Amp 3-Phase Main Power Cable (05m Length)
2Distro-LSC APS 12-Channel GPO Smart Power Distribution Racks
2Soco Cable Assemblies (30m + Integrated DMX 5-Pin line)
4Soco Cable Termination Blocks (2x Female Fixture-End // 2x Male System-End)
CREW & ATMOSPHERE1Look Solutions Unique 2.1 Digital Atmospheric Hazer
7Operational Crew Allocation: 3x Load In (4hr), 1x Show Operator, 3x Load Out (4hr)

B. TOURING CONCERT OVERHEAD LIGHTING RIG [QUANTITY LOG]

TRUSS SECTOR LOCATIONQTYINTEGRATED HARDWARE FIXTURE / PROFILE CONTROL
FRONT TRUSS8Ayrton Eurus Moving Head Profile automated units
MID TRUSS4Ayrton Eurus Moving Head Profile automated units
4Chauvet Maverick Mk2 Moving Head Wash systems
2Chauvet Strike Saber 10-Way Linear Blinder Bars
BACK TRUSS4Ayrton Eurus Moving Head Profile automated units
4Chauvet Maverick Mk2 Moving Head Wash systems
4Chauvet Maverick Mk3 High-Output Moving Head Wash units
6Chauvet Rogue R3 Moving Head Beam fixtures
CONSOLE, DISTRO & BLINDERS6Chauvet Rogue R3 Moving Head Beams (Additional Frame Deployment)
6Chauvet Strike Saber 10-Way Linear Blinder Bars (Flown Split Configuration)
1Onyx NX2 Console // 1x EN12 Node // 3x EN4 Nodes // 1x NS8 Network Switch
5Distro-LSC APS 12-Channel GPO Smart Power Distribution Framework Racks
POWER, LOOMS & FX2Look Solutions Unique 2.1 Hazers // 1x 63A 3-Phase Main (5m) // 3x Soco Line Sets

C. PERFORMANCE MOTOR LIFTS & RIGGING SYSTEMS [QUANTITY LOG]

RIGGING SYSTEM PACKAGEQTYCOMPONENTS & SPECIFIC HOIST HARDWARE
PACKAGE 1:
2-POINT TRUSS UPSET
6CM Lodestar NH D8+ 1-Ton Electric Chain Hoists (20m Lift Paths)
1SRS 12-Way Low-Voltage (LV) Master Motor Controller Unit
63.0-Ton Capacity Heavy-Duty Structural Girder / Beam Clamps
6Rigging Bottom Points // 3x Strain Reliefs // 3x Motor Breakouts (Motor End)
PACKAGE 2:
3-POINT HIGH-CAPACITY UPSET
9CM Lodestar NH D8+ 1-Ton Electric Chain Hoists (20m Lift Paths)
1SRS 12-Way Low-Voltage (LV) Master Motor Controller Unit
93.0-Ton Capacity Heavy-Duty Structural Girder / Beam Clamps
9Rigging Bottom Points // 3x Strain Reliefs // 3x Motor Breakouts (Motor End)
-Loom Arrays: 1x 4-way (15m), 1x 4-way (20m), 1x 4-way (30m), 3x single (3m/10m/20m)